Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Biomed Chromatogr ; 34(10): e4906, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32449534

RESUMO

Tacrine derivatives containing iodobenzoic acid were developed as a novel multitarget-directed ligand and find potential application in the treatment of Alzheimer's disease. The aim of this study is to perform a physicochemical profile of this series. Experimental log P and pKa values were determined and compared with those already calculated. The results indicated better values of the tested compounds than the values predicted using computer software. The stability report was obtained using the developed HPLC method. The stability assay in different environment conditions provided information about the photosensitivity of these compounds and a proper method for the storage of this series of compounds.


Assuntos
Inibidores da Colinesterase , Iodobenzoatos , Tacrina , Doença de Alzheimer , Inibidores da Colinesterase/análise , Inibidores da Colinesterase/química , Inibidores da Colinesterase/metabolismo , Cromatografia Líquida de Alta Pressão , Descoberta de Drogas , Estabilidade de Medicamentos , Humanos , Iodobenzoatos/análise , Iodobenzoatos/química , Iodobenzoatos/metabolismo , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Tacrina/análogos & derivados , Tacrina/análise , Tacrina/química , Tacrina/metabolismo
2.
Int J Mol Sci ; 20(12)2019 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-31234471

RESUMO

Radionuclide molecular imaging of human epidermal growth factor receptor 2 (HER2) in breast and gastroesophageal cancer might be used to stratify patients for HER2-targeted therapy as well as monitor treatment response and disease progression. Designed ankyrin repeat proteins (DARPins) are small engineered scaffold proteins with favorable properties for molecular imaging. Herein we compared two methods for labeling the anti-HER2 DARPin (HE)3-G3, direct and indirect radioiodination. We hypothesized that the use of N-succinimidyl-para-iodobenzoate (SPIB) for radioiodination would facilitate the clearance of radiometabolites and improve the contrast of imaging. Both radiolabeled (HE)3-G3 variants preserved their binding specificity and high affinity to HER2-expressing cells. The specificity of tumor targeting in vivo was also demonstrated. A biodistribution comparison of [125I]I-(HE)3-G3 and [125I]I-PIB-(HE)3-G3, in mice bearing HER2 expressing SKOV3 xenografts, showed rapid clearance of [125I]I-PIB-(HE)3-G3 from normal organs and tissues and low accumulation of activity in organs with NaI-symporter expression. Both radiolabeled (HE)3-G3 variants had equal tumor uptake. Consequently, the indirect label provided higher tumor-to-blood and tumor-to-organ ratios compared with the direct label. Comparative Single Photon Emission Computed Tomography (SPECT)/CT imaging of HER2 expression in SKOV3 xenografts, using both radiolabeled DARPins, demonstrated the superior imaging contrast of the indirect label. Indirect radioiodination of (HE)3-G3 using SPIB could be further applied for SPECT and PET imaging with iodine-123 and iodine-124.


Assuntos
Repetição de Anquirina , Radioisótopos do Iodo/análise , Iodobenzoatos/análise , Neoplasias Ovarianas/diagnóstico por imagem , Receptor ErbB-2/análise , Animais , Linhagem Celular Tumoral , Feminino , Humanos , Camundongos , Camundongos Endogâmicos BALB C , Imagem Molecular/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
3.
Environ Int ; 86: 107-18, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26571428

RESUMO

This work analyses the presence of forty-eight emerging pollutants, including twenty-five drugs of abuse and metabolites, seventeen cytostatic drugs and six iodinated contrast media, in tap water from the Madrid Region. Analysis of the target compounds in the tap water was performed by means of (on-line or off-line) solid-phase extraction followed by analysis by liquid chromatography-tandem mass spectrometry. A preliminary human health risk characterization was undertaken for each individual compound and for different groups of compounds with a common mechanism of action found in tap water. The results of the study showed the presence of eight out of the twenty-five drugs of abuse and metabolites analysed, namely, the cocainics cocaine and benzoylecgonine, the amphetamine-type stimulants ephedrine, 3,4-methylenedioxymethamphetamine and methamphetamine, the opioid methadone and its metabolite 2-ethylene-1,5-dimethyl-3,3-diphenylpyrrolidine and, finally caffeine at concentrations ranging from 0.11 to 502 ng L(-1). Four out of the six analysed iodinated contrast media, namely, diatrizoate, iohexol, iomeprol and iopromide, were detected in at least one sample, with concentration values varying between 0.4 and 5 ng L(-1). Cytostatic compounds were not detected in any sample. Caffeine was the substance showing the highest concentrations, up to 502 ng L(-1), mainly in the drinking water sampling point located in Madrid city. Among the other drugs of abuse, the most abundant compounds were cocaine and benzoylecgonine, detected at concentrations ranging from 0.11 to 86 ng L(-1) and from 0.11 to 53 ng L(-1), respectively. Regarding iodinated contrast media, iohexol was the most ubiquitous and abundant compound, with a frequency of detection of 100% and concentrations from 0.5 to 5.0 ng L(-1) in basically the same range in all sampling points. Taking into account the results and types of treatment applied, ozonisation plus granular activated carbon filtration appears to be efficient in the removal of cocaine and benzoylecgonine. For the amphetamine-type stimulants, opioids and caffeine, ozonisation plus granular activated carbon filtration and ultrafiltration plus reverse osmosis showed higher removal efficiency than sand filtration. The human health risk characterization performed indicates that the lifetime consumption of the tap waters analysed has associated a negligible human health concern.


Assuntos
Meios de Contraste/análise , Citostáticos/análise , Água Potável/análise , Monitoramento Ambiental/métodos , Drogas Ilícitas/análise , Iodobenzoatos/análise , Poluentes Químicos da Água/análise , Cromatografia Líquida , Água Potável/normas , Humanos , Espectrometria de Massas , Saúde Pública , Medição de Risco , Extração em Fase Sólida , Espanha , Purificação da Água/métodos
4.
Anal Bioanal Chem ; 384(1): 302-8, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16328244

RESUMO

FT-IR and Raman experimental data were assigned to appropriate bond vibrations and used to compare the different electronic charge distributions in the aromatic rings and carboxylic anions of various lithium, sodium, potassium, rubidium and caesium o-iodobenzoates and picolinates. Then principal component analysis (PCA) was applied in order to attempt to distinguish the biological activities of these compounds according to selected band wavenumbers. The growth of the bacteria Escherichia coli and Bacillus subtilis and the yeasts Saccharomyces cerevisiae and Hansenula anomala under optimal growth conditions were measured after 24 hours of incubation by the classical plate method. The influence of the picolinates and o-iodobenzoates on the growth of these microorganisms, again after 24 hours of incubation, was also measured and compared to the effect of sodium benzoate, which was used as a reference material. In general, the o-iodobenzoates exhibited more activity against the microorganisms than the picolinates. A statistically significant linear correlation between the spectral data and the degree of influence of a given compound on microorganism growth was established. The correlation coefficients for the o-iodobenzoates were 0.696, -0.628, 0.693 and 0.755 for E. coli, B. subtilis, H. anomala and S. cerevisiae, respectively, and for the picolinates they were 0.818, 0.826, 0.821 and 0.877 for E. coli, B. subtilis, H. anomala and S. cerevisiae, respectively. Therefore, IR spectroscopy is shown to be a rapid and reliable analytical tool for preliminary estimation of the antimicrobial properties of newly synthesized compounds, that can be applied before microbial performance tests.


Assuntos
Iodobenzoatos/análise , Iodobenzoatos/química , Metais Alcalinos/análise , Metais Alcalinos/química , Ácidos Picolínicos/análise , Ácidos Picolínicos/química , Vibração , Bacillus subtilis/química , Escherichia coli/química , Saccharomycetales/química , Espectrofotometria Infravermelho , Análise Espectral Raman
5.
Acta Radiol ; 28(5): 523-6, 1987.
Artigo em Inglês | MEDLINE | ID: mdl-2960342

RESUMO

Six lactating women undergoing contrast media examination had milk and blood taken to determine the rate and extent of excretion of iohexol (Omnipaque) (four mothers) and metrizoate (Isopaque) (two mothers). Blood samples were taken up to 45 minutes and milk samples up to 48 hours after the contrast medium injection. The excretion was low, reaching a maximum at 3 to 6 hours and showing a slow decay curve (t1/2 = 15 to 108 hours). One mother, who was weaning her baby, showed a different excretion pattern. The amount excreted during 24 hours was about 0.5 per cent of the weight adjusted maternal dose for both iohexol and metrizoate. It is not likely, that such a low dose of poorly absorbed drug would cause any adverse effects in the infant, unless it is hypersensitive to the drug already. The authors consider breast feeding to be acceptable for mothers receiving iohexol or metrizoate.


Assuntos
Iodobenzoatos/análise , Iohexol/análise , Ácido Metrizoico/análise , Leite Humano/análise , Adulto , Feminino , Humanos , Iohexol/sangue , Iohexol/farmacocinética , Ácido Metrizoico/sangue , Ácido Metrizoico/farmacocinética , Peso Molecular
8.
Radiology ; 140(1): 127-34, 1981 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-7244214

RESUMO

The use of computed tomography (CT) to estimate the differences in radiographic contrast obtainable with different contrast agents is discussed. A CT scanner was calibrated to measure the in vivo iodine concentration, and phantom studies were performed to derive the relationship between iodine concentration and resultant radiographic contrast in the kidneys. The technique is illustrated by a quantitative comparison of the nephrographic phase in dogs with two urographic contrast agents, sodium iothalamate and sodium ioxaglate.


Assuntos
Meios de Contraste/análise , Iodobenzoatos/análise , Ácido Iotalâmico/análise , Rim/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ácidos Tri-Iodobenzoicos/análise , Animais , Calibragem , Cães , Feminino , Iodo/análise , Ácido Ioxáglico , Intensificação de Imagem Radiográfica
10.
Nuklearmedizin ; 17(2): 53-6, 1978 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-662700

RESUMO

100 muCi 125I-Orthoiodohippurate were injected i. v. to 2 Wistar rats. Urine and faeces were analysed by means of thin-layer chromatography and high-pressure liquid chromatography. The combined metabolic balance resulted in the following findings: Rat 1: 15% 125I-Orthoiodobenzoic acid, 66% 125I-Orthoiodohippuric acid and 12,5% 125I-iodide. Rat 2: 18,5% 125I-Orthoiodobenzoic acid, 67,5% 125I-Orthoiodohippuric acid and 10,2% 125I-iodide.


Assuntos
Ácido Iodoipúrico/análogos & derivados , Ácido Iodoipúrico/metabolismo , Animais , Cromatografia Líquida de Alta Pressão , Cromatografia em Camada Delgada , Fezes/análise , Iodetos/análise , Iodetos/urina , Iodobenzoatos/análise , Iodobenzoatos/urina , Ácido Iodoipúrico/análise , Ácido Iodoipúrico/urina , Ratos
11.
Br J Radiol ; 51(601): 17-9, 1978 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-620113

RESUMO

An extremely simple spectrophotometric method for measuring biliary ioglycamide (meglumine ioglycamate) concentration is described. It was validated by a radioactive technique.


Assuntos
Bile/análise , Iodobenzoatos/análise , Ácido Ioglicâmico/análise , Humanos , Infusões Parenterais , Radioisótopos do Iodo , Espectrofotometria Ultravioleta/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...